A
A.1 Parameter list
A-733
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
The following parameters are available for the ”SIMODRIVE 611 uni-
versal” control board:
Version: 08.03.07
0001 Actual traversing block – block number
Min Standard Max Unit Data type Effective
Integer16 RO
... in the ”Positioning” mode and for the ”spindle positioning” function it specifies the block num-
ber of the traversing block being processed.
Note: refer to the index entry ”Traversing blocks” or P0080:64
0002 Actual traversing block – position
Min Standard Max Unit Data type Effective
MSR Integer32 RO
... in the ”Positioning” mode and for the ”spindle positioning” function it specifies the pro-
grammed position of the traversing block being processed.
Note: refer to the index entry ”Traversing blocks” or P0081:64
0003 Actual traversing block – velocity
Min Standard Max Unit Data type Effective
c*MSR/min Unsigned32 RO
... in the ”Positioning” mode and for the ”spindle positioning” function it specifies the pro-
grammed velocity of the traversing block being processed.
Note: refer to the index entry ”Traversing blocks” or P0082:64
0004 Actual traversing block – acceleration override
Min Standard Max Unit Data type Effective
% Unsigned16 RO
... in the ”Positioning” mode and for the ”Spindle positioning” function it specifies the pro-
grammed acceleration override of the traversing block being processed.
Note: refer to the index entry ”Traversing blocks” or P0083:64
0005 Actual traversing block – deceleration override
Min Standard Max Unit Data type Effective
% Unsigned16 RO
... in the ”Positioning” mode and for the ”Spindle positioning” function it specifies the pro-
grammed deceleration override of the traversing block being processed.
Note: refer to the index entry ”Traversing blocks” or P0084:64
0006 Actual traversing block – command
Min Standard Max Unit Data type Effective
Unsigned16 RO
... in the ”Positioning” mode specifies the programmed command of the traversing block being
processed.
Note: refer to the index entry ”Traversing blocks” or P0085:64
0007 Actual traversing block – command parameter
Min Standard Max Unit Data type Effective
Unsigned16 RO
... in the ”Positioning” mode specifies the programmed command parameter of the traversing
block being processed.
Note: refer to the index entry ”Traversing blocks” or P0086:64