A.1 Parameter list
A-753
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0326 Standstill window
Min Standard Max Unit Data type Effective
0 200 20000 MSR Unsigned32 immed.
... defines the standstill window, in which the position actual value must be after the standstill
monitoring time has expired (P0325).
>= 1 The standstill monitoring is active with this value
0 Monitoring is de-activated
Note: refer to the index entry ”Standstill monitoring”
0338 Fault response, illegal input signals (–> 7.1)
Min Standard Max Unit Data type Effective
0 1 2 Hex Unsigned16 immed.
... defines the fault response which is initiated for an illegal combination of input signals.
Example: When starting a traversing block, the input signal ”Operating conditions/reject travers-
ing task” is not set.
0 No output
1 A warning is output
2 Fault 196 is output with the warning number as supplementary information
This involves signal combinations, which result in warnings 804,805,806,807,808,809,840,845.
0400 Reference point coordinates, master drive (–> 4.1)
Min Standard Max Unit Data type Effective
–200000000 0 200000000 MSR Integer32 immed.
... defines the reference point coordinates of the master drive.
0401 Coupling factor, master drive revolutions (–> 3.3)
Min Standard Max Unit Data type Effective
1 1 8388607 – Unsigned32 PO
... defines the coupling factor between the master and slave drive.
0402 Coupling factor slave drive revolutions (–> 3.3)
Min Standard Max Unit Data type Effective
1 1 8388607 – Unsigned32 PO
... defines the coupling factor between the master and slave drive.