A.1 Parameter list
A-759
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
0626 Signal number analog output term. 75.x/15
Min Standard Max Unit Data type Effective
0 34 530 Unsigned16 immed.
... defines which signal is output via terminal 75.x/15.
In this case the appropriate signal number must be entered from the ”Signal selection list for
analog output”.
Note: refer to the index entry ”Analog outputs”
0627 Shift factor analog output term. 75.x/15
Min Standard Max Unit Data type Effective
0 0 47 Unsigned16 immed.
... defines the shift factor, with which the analog signal is manipulated.
An 8 bit window of the 24/48 bit signal can be represented via the DAC. Thus, the shift factor
must be used to define which window of the internal 24/48 bit is to be displayed.
Note: refer to the index entry ”Analog outputs”
0628 Offset analog output term. 75.x/15
Min Standard Max Unit Data type Effective
–128 0 127 Integer16 immed.
... specifies an offset for the 8-bit output signal.
Note: refer to the index entry ”Analog outputs”
0629 Segment address analog output term. 75.x/15
Min Standard Max Unit Data type Effective
0 0 2 Unsigned16 immed.
Note: Internal Siemens
0630 Offset address analog output term. 75.x/15
Min Standard Max Unit Data type Effective
0 0 FFFFFF Hex Unsigned32 immed.
Note: Internal Siemens
0631 Bias protection, analog output, term. 75.x/15
Min Standard Max Unit Data type Effective
0 1 1 Unsigned16 immed.
... switches the bias protection on or off.
1 bias protection on
The bits above the 8-bit window result in an output of +10 V or –10 V, i. e. the output cannot be
over-modulated.
0 bias protection off
The bits above the 8-bit window are ignored.
The analog value is defined exclusively by the 8-bit value, i.e. the output can be overmodulated.
Note: refer to the index entry ”Analog outputs”
0632 Smoothing time, analog output, terminal 75.x/15
Min Standard Max Unit Data type Effective
0.0 0.0 1000.0 ms Floating Point immed.
... smooths the output signal with a 1st order proportional element (PT1 element, low pass fil-
ter).
0.0 filter is inactive
Note: refer to the index entry ”Analog outputs”