A.1 Parameter list
A-836
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1503:8 Time constant, speed setpoint filter 2 (ARM SRM)
Time constant, velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
0.0 0.0 500.0 ms Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1506:8 Natural frequency, speed setpoint filter 1 (ARM SRM)
Natural frequency, velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
10.0 2000.0 8000.0 Hz Floating Point immed.
Note:
The filter can be switched out/switched in via the ”First speed setpoint filter off” input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1507:8 Damping, speed setpoint filter 1 (ARM SRM)
Damping, velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
0.2 0.7 5.0 Floating Point immed.
Note:
The filter can be switched out/switched in via the ”First speed setpoint filter off” input signal.
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1508:8 Natural frequency, speed setpoint filter 2 (ARM SRM)
Natural frequency, velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
10.0 2000.0 8000.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1509:8 Damping, speed setpoint filter 2 (ARM SRM)
Damping, velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
0.2 0.7 5.0 Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1514:8 Blocking frequency, speed setpoint filter 1 (ARM SRM)
Blocking frequency, velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
1.0 3500.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
A Lists
01.99
! 611ue diff !
04.05