A.1 Parameter list
A-837
 Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1515:8 Bandwidth, speed setpoint filter 1 (ARM SRM)
Bandwidth, velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
5.0 500.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1516:8 Numerator, bandwidth speed setpoint filter 1 (ARM SRM)
Numerator, bandwidth velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
0.0 0.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1517:8 Blocking frequency, speed setpoint filter 2 (ARM SRM)
Blocking frequency, velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
1.0 3500.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1518:8 Bandwidth, speed setpoint filter 2 (ARM SRM)
Bandwidth, velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
5.0 500.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1519:8 Numerator, bandwidth speed setpoint filter 2 (ARM SRM)
Numerator, bandwidth velocity setpoint filter 2 (SLM)
Min Standard Max Unit Data type Effective
0.0 0.0 7999.0 Hz Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2
1520:8 BSP natural frequency, speed setpoint filter 1 (ARM SRM)
BSF natural frequency velocity setpoint filter 1 (SLM)
Min Standard Max Unit Data type Effective
1.0 100.0 141.0 % Floating Point immed.
Note:
The speed setpoint filters are described in:
References: /FBA/, Description of Functions, Drive Functions, Section DD2