A
A.1 Parameter list
A-841
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1611 Response threshold dn/dt
Min Standard Max Unit Data type Effective
0 300 1600 % Unsigned16 immed.
Note: Internal Siemens
1612 Shutdown response, faults 1 (–> 3.3)
Min Standard Max Unit Data type Effective
0 83B2 FFFF Hex Unsigned32 immed. (ARM)
0 3B2 FFFF Hex Unsigned32 immed. (SRM SLM)
... defines how the system responds to the listed faults.
Bit 1 Measuring circuit fault, absolute current (fault 501)
Bit 4 Measuring circuit fault, motor measuring system (fault 504)
Bit 5 Measuring circuit fault, motor measuring system, absolute track (fault 505)
Bit 7 Synchronizing error, rotor position (fault 507)
Bit 8 Zero mark monitoring, motor measuring system (fault 508)
Bit 9 Drive converter limiting frequency exceeded (fault 509)
Bit 12 Measuring circuit error, direct measuring system (fault 512)
Bit 13 Measuring circuit fault, direct measuring system absolute track (fault 513)
Bit 14 Zero mark monitoring, direct measuring system (fault 514)
Bit 15 Heatsink temperature exceeded (fault 515)
Note:
Bit x = ”1” ––> STOP 1 is executed (internal pulse cancellation)
Bit x = ”0” ––> STOP II is executed (internal controller inhibit)
If bit 1 is disabled, then this can destroy the power module (SIMODRIVE 611).
1613 Shutdown response, faults 2 (–> 3.3)
Min Standard Max Unit Data type Effective
0 7FCE 3FFFF Hex Unsigned32 immed. (ARM)
0 100 3FFFF Hex Unsigned32 immed. (SRM SLM)
... defines how the system responds to the listed faults.
Bit 1 AD conversion error, terminal 56/14 or terminal 24/20 (fault 601)
Bit 2 Open-loop torque controlled operation w/o encoder not permissible (fault 602)
Bit 3 Changeover to a non-parameterized motor data set (fault 603)
Bit 5 Position controller output limited (fault 605)
Bit 6 Flux controller output limited (fault 606)
Bit 7 Current controller output limited (Fault 607)
Bit 8 Speed controller output limited (fault 608)
Bit 9 Encoder limiting frequency exceeded (fault 609)
Bit 10 Rotor position identification has failed (Fault 610)
Bit 11 Illegal motion during rotor position identification (fault 611)
Bit 12 Illegal current during rotor position identification (fault 612)
Bit 13 Shutdown limit, motor overtemperature (P1607) exceeded (fault 613)
Bit 14 Delayed shutdown for motor overtemperature (P1602 and P1603) (fault 614)
Bit 15 Direct measuring system, encoder limiting frequency exceeded (fault 615)
Bit 16 DC link undervoltage (Fault 616)
Bit 17 DC link overvoltage (Fault 617)
Note:
Bit x = ”1” ––> STOP 1 is executed (internal pulse cancellation)
Bit x = ”0” ––> STOP II is executed (internal controller inhibit)
A Lists
01.99
! 611ue diff !
04.05