A.1 Parameter list
A-842
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1615 Tolerance rotational accuracy monitor
Min Standard Max Unit Data type Effective
0.0 0.2 100.0 m/min Floating Point immed. (SLM)
0.0 2.0 100.0 rpm Floating Point immed. (SRM ARM)
Note: Internal Siemens
1616 Diagnosis, actual speed value
Min Standard Max Unit Data type Effective
– – – – Unsigned16 RO
When continuously increased by several increments, there is an increased noise level (the
speed actual value is faulty).
1620 Bits for variable signaling function
Min Standard Max Unit Data type Effective
0 0 7 Hex Unsigned16 immed.
... defines the behavior of variable message function.
Bit 0 Variable message function
Bit 0 = 1 Active
Bit 0 = 0 Inactive
Bit 1 Segment, variable message function
Bit 1 = 1 Address space Y
Bit 1 = 0 Address space X
Bit 2 Comparison, signed
Bit 2 = 1 Comparison with sign
Bit 2 = 0 Comparison without sign
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1621 Signal number, variable signaling function
Min Standard Max Unit Data type Effective
0 0 530 – Unsigned16 immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1622 Address, variable signaling function
Min Standard Max Unit Data type Effective
0 0 FFFFFF Hex Unsigned32 immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
1623 Threshold, variable signaling function
Min Standard Max Unit Data type Effective
FF000001 0 FFFFFF Hex Integer32 immed.
Note:
Parameterize ”variable message function” in the selection box with SimoCom U.
Refer under the index entry ”Variable message function”
04.05