A
A.1 Parameter list
A-844
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1653 Minimum value Min/Max memory
Min Standard Max Unit Data type Effective
– – – Hex Unsigned32 RO
Displays the min. value in the min/max memory.
1654 Maximum value Min/Max memory
Min Standard Max Unit Data type Effective
– – – Hex Unsigned32 RO
Displays the max. value in the min/max memory.
1655 Segment memory location monitor
Min Standard Max Unit Data type Effective
0 0 1 Hex Unsigned16 immed.
Select the segment for the monitor function.
0 Segment X: (Monitor)
1 Segment Y: (Monitor)
1656 Address memory location monitor
Min Standard Max Unit Data type Effective
0 0 FFFFFF Hex Unsigned32 immed.
Select the address for the monitor function.
1657 Value display monitor
Min Standard Max Unit Data type Effective
– – – Hex Unsigned32 RO
Displays the contents of the address in P1655/P1656.
1658 Value input monitor
Min Standard Max Unit Data type Effective
0 0 FFFFFF Hex Unsigned32 immed.
Note: Internal Siemens
1659 Value acceptance monitor
Min Standard Max Unit Data type Effective
0 0 1 – Unsigned16 immed.
Note: Internal Siemens
1701 DC link voltage
Min Standard Max Unit Data type Effective
– – – V(pk) Unsigned16 RO
... is used for continuous display (measurement) of the DC link voltage.
Note:
If a value > 0 V is in P1161 (fixed DC link voltage), then this display is not valid.
The DC link voltage is centrally measured at the NE module. This means that the DC link con-
nection to the drive modules cannot be checked using P1701.
1703 Lead time, motor measuring system conversion
Min Standard Max Unit Data type Effective
–––µs Unsigned16 RO
Note: Internal Siemens
04.05