A
A.1 Parameter list
A-845
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1705 Voltage setpoint (rms)
Min Standard Max Unit Data type Effective
V(RMS) Floating Point RO
Displays the phase-to-phase voltage.
1708 Torque-generating current Iq
Min Standard Max Unit Data type Effective
% Floating Point RO
... displays the torque-generating current Iq RMS.
Note:
The display of the torque generating current actual value is smoothed using a PT1 filter
(P1250).
The smoothed current actual value is displayed as an absolute percentage, where 100 % corre-
sponds to the maximum power module current (e. g. for an 18/36 A power module ––> 100 % =
36 A RMS).
1709 Significance, voltage representation
Min Standard Max Unit Data type Effective
Floating Point RO
Note: Internal Siemens
1710 Significance, current representation
Min Standard Max Unit Data type Effective
–––µA(pk) Floating Point RO
Note: Internal Siemens
1711 Significance, speed representation (ARM SRM)
Significance, velocity representation (SLM)
Min Standard Max Unit Data type Effective
m/min Floating Point RO (SLM)
rpm Floating Point RO (SRM ARM)
Note: Internal Siemens
1712 Significance, rotor flux representation (ARM)
Min Standard Max Unit Data type Effective
–––µVs Floating Point RO (ARM)
Note: Internal Siemens
1713 Significance torque representation (ARM SRM)
Significance, force representation (SLM)
Min Standard Max Unit Data type Effective
–––µN Floating Point RO (SLM)
–––µNm Floating Point RO (SRM ARM)
Note: Internal Siemens
1716 Torque setpoint (ARM SRM)
Force setpoint (SLM)
Min Standard Max Unit Data type Effective
N Floating Point RO (SLM)
Nm Floating Point RO (SRM ARM)
... displays the actual torque setpoint or force setpoint (SLM).
Note:
The torque/force setpoint display is smoothed using a PT1 filter (P1252).
A Lists
01.99
! 611ue diff !
04.05

Table of Contents