A.1 Parameter list
A-846
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
1717 Limiting factor for torque/power (ARM SRM)
Limiting factor for force/power (SLM)
Min Standard Max Unit Data type Effective
– – – % Floating Point RO
... displays the actual limiting factor for torque/power or force/power (SLM).
Note:
refer to the index entry ”Torque/power reduction”
1718 Torque-generating current Iq (A) (–> 3.1)
Min Standard Max Unit Data type Effective
– – – A(rms) Floating Point RO
... displays the torque-generating current Iq as RMS value.
Note:
The display of the torque-generating current actual value is smoothed using a PT1 filter
(P1250).
1719 Actual absolute current (rms)
Min Standard Max Unit Data type Effective
– – – A(rms) Floating Point RO
Displays the motor phase current RMS.
1723 Diagnosis, ramp-up time
Min Standard Max Unit Data type Effective
– – – ms Unsigned16 RO
Note: Internal Siemens
1724 Diagnosis, rotational accuracy monitor
Min Standard Max Unit Data type Effective
– – – – Unsigned16 RO
Note: Internal Siemens
1725 Normalization of torque setpoint (ARM SRM) (–> 2.4)
Normalization of force setpoint (SLM)
Min Standard Max Unit Data type Effective
– – – N Floating Point RO (SLM)
– – – Nm Floating Point RO (SRM ARM)
... specifies the reference value for the status word Mset for PROFIBUS.
The following applies before SW 4.1: The value corresponds to 800% of the rated motor torque.
From SW 4.1 the following applies: The value corresponds to P0882 * rated motor torque.
1726 Calculated jerk time (–> 3.1)
Min Standard Max Unit Data type Effective
– – – ms Floating Point RO
... displays the calculated jerk time which is currently effective.
Note: refer to the index entry ”Jerk limitation”
1729 Actual rotor position (electrical) (–> 3.3)
Min Standard Max Unit Data type Effective
– – – Degree Floating Point RO
...displays the actual electrical rotor position.
04.05