A
A.3 List of motors
A-870
Siemens AG 2005 All Rights Reserved
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
Table A-5 Unlisted motor: Parameters for permanent–magnet synchronous
motors with field weakening
Parameters
No. Name Units Value
1015 Activate PE–MSD
1 = activated, 0 = de–activated
1
1102 Motor code number 1999
1103 Rated motor current A(rms)
1104 Maximum motor current A(rms)
1112 Motor pole pair number
1113 Torque constant Nm/A
1114 Voltage constant V(rms)
1115 Armature resistance (phase value)
(rotating field inductance: L
rotating
field
= 1.5
L
phase
)
1116 Armature inductance mH
1117 Motor moment of inertia kgm
2
1118 Motor standstill current A(rms)
1122 Motor limiting current A(rms)
1128 Optimum load angle (from SW 3.3) Degr.
1136 Motor short–circuit current A(rms)
1142 Speed at the start of field weakening RPM
1145 Stall (standstill) torque reduction factor %
1146 Maximum motor speed RPM
1149 Reluctance torque constant (from SW 3.3) mH
1180 Lower current limit, current controller adapta-
tion
%
1181 Upper current limit, current controller adapta-
tion
%
1182 Factor, current controller adaptation %
1400 Rated motor speed RPM
Parameters for
unlisted motors
(PE spindle)
A Lists
01.99

Table of Contents