Applications
12.5 Motor changeover
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
925
Function diagrams (see SINAMICS S120/S150 List Manual)
8565
- Drive Data Sets (DDS)
8570
- Encoder Data Sets (EDS)
8575
- Motor Data Sets (MDS)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0051[0...4]
CO/BO: Drive data set DDS effective
p0130
data sets (MDS) number
p0140
Encoder data sets (EDS) number
p0180
Drive data set (DDS) number
p0186 [0...n]
Motor data set (MDS) number
p0187[0...n]
Encoder 1 encoder data set number
p0188[0...n]
Encoder 2 encoder data set number
p0189[0...n]
3 encoder data set number
p0820[0...n]
BI: Drive data set selection DDS, bit 0
p0824[0...n]
BI: Drive data set selection DDS, bit 4
p0826 [0...n]
Motor changeover, motor number
p0827 [0...n]
Motor changeover status word bit number
p0828 [0...n]
BI: Motor changeover feedback
r0830.0...15
CO/BO: Motor changeover status word
p0831[0...15]
BI: Motor changeover contactor feedback
p0833
Data set changeover configuration