DC link components
8.6 Control Supply Module CSM
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
531
WARNING
Fire hazard due to overheating because of inadequate ventilation clearances
Inadequate ventilation clearances can cause overheating with a risk for personnel due to
smoke and fire. This can also result in increased failure rates and a shorter service life of
the component.
• Maintaining 80 mm ventilation clearances above and below the component is essential.
NOTICE
Material damage due to loose power connections when using the 24 V terminal adapter
Insufficient tightening torques or vibration can result in faulty electrical connections. This
can cause fire damage or malfunctions.
• When using the 24 V terminal adapter, it must be screwed onto the Control Supply
Module. Tighten the enclosed EJOT-PT K30 x 16 screw with the specified tightening
torque (0.5 Nm).
• Check the tightening torques of all power connections at regular intervals and tighten
them when required. This applies in particular after transport.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals