Accessories
11.3 Reinforced DC link busbars
Booksize Power Units
624 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
11.3.5
Installing the reinforced DC link busbars
Required tools:
Torx screwdriver T20 for DC link screws (Torx slot)
Table 11- 13 Installing the reinforced DC link busbars
1. Install the reinforced DC link busbars, starting at the left.
2. Attach the DC link busbars using the original M4x20
screws at the right-hand side of the component.
Do not tighten the screws with their final tightening torque
yet.
3. Install the reinforced DC link busbars, and attach these at
the right-hand side of all of the remaining components.