Accessories
11.5 DC link adapter
Booksize Power Units
642 Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
11.5.3.2
DC link connection
Table 11- 22 DC link connection
Terminal
Function
DCP
DC link positive
DCN
DC link negative
WARNING
Danger to life due to electric shock and risk of fire when the necessary clearances and
creepage distances are not complied with
When using non-insulated end sleeves, the required clearances and creepage distances
are not complied with! This can result in flashover between the cables and the undesirable
formation of arcs. As a consequence, there is a risk of electric shock and fire.
• Only use DC link connecting cables with insulated end sleeves.