Parameter Default val‐
ue
Value
range
Access
level
Description
510 Fixed flow mode enable Yes No, Yes R/W Select "Yes" to force the device to show a
fixed flow value
Default must be "No"
Always manually reset the value to "No"
511 Fixed flow value 0 -1E+09 to
1E+09
R/W Fixed flow value for enabled fixed flow
515 Controlling output A and B Auto Auto,
Forced
HW key Control of output A and B is used to stop or
force the output A and/or B.
For editing, use device menu "Service".
Valid if pulse output is enabled
Power
130 Consumed battery capacity e.g.
2.054239
Ah
Read The amount of energy consumed since last
time the battery was replaced.
Valid only for battery-powered versions
501 Operating hours since pow‐
er up
1105 h 3.4 E+38 Read Total operation hours since first power up
503 Numbers of power up e.g. 4 0 to 65535 Read Total number of power-ups since first power-
up.
540 Battery change enable No No, Yes R/W Select "Yes" to set battery installation date to
current date and reset remaining battery op‐
eration capacity to maximum.
Valid only for battery-powered versions
541 Battery installation date last battery
installation
date
dd-mm-
yyyy;
hh:mm:ss
Read Latest installation date of batteries.
Valid only for battery-powered versions
542 Power supply mode Product de‐
pendent
Battery on‐
ly, Mains
only, Mains
with back‐
up battery.
Read The flowmeter is either powered by battery
only, mains only or by mains with battery
backup.
The type is defined by the order code and
cannot be changed.
543 Actual battery capacity Product de‐
pendent
0 to 50 R/W** The capacity of the battery in Ah
- Single 16.5 Ah
- Dual battery pack 33.0 Ah
Valid only for battery-powered versions
544 Battery alarm limit 80 0 to 90 R/W Present an alarm when the consumed ener‐
gy superceeds this percentage of the battery
capacity.
Valid only for battery-powered versions
* Not supported for FUS080
** Maintenance = Read only
Parameter lists
A.3 Diagnostics
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE 105