Select the operation to be carried out on the selected key:
1) Reading + Cutting: the key and cutting data are read
without interruption
.
2) Cutting only: the previously read key is cut.
3) Reading only: the key is read;
in this way the cuts read can be edited before cutting the key
.
4) Editing of key read: the original key read can be edited in order to adjust any defects or broken parts (see
ch. 5.15, page 61).
SELECT TYPE OF KEY
3 - Pump 7 - Rear stop
0 - Bit stop male 4 - Square-square tip 8 - Rear stop french
1 - Bit stop female 5 - Square-round tip 9 - Small bit
2 - Shoulder stop 6 - Square stepped tip 10 - Special bit female
1 - Reading + Copying
2 - Cutting only
3 - Reading only
4 - Post-Reading adj.
Bit stop
MALE
Bit stop
FEMALE
SHOULDER
stop
keys
PUMP
tip
SQUARE
tip
SQUARE-ROUND
STEPPED tip
SQUARE
REAR
STOP
Special
BIT FEMALE
Small
BIT
MUEL PUMP