7.11.1 Machine zero setting after replacing the photocells
CUTTING UNIT
1) enter ‘Maintenance’ menu #5.
2) select ‘Machine zero points’ #2.
3)
select ‘Cutting unit’ #1
.
4) install the (Z13) template.
5) remove the cutter from the machine and install the (Z12)
template.
6) manually move the X and Y axes up until the templates
make contact.
7) lower the protective shield and press START.
ATTENTION: check that both the (Z13) and (Z12) templates make
perfect contact. If this does not occur the display will
show an error message.
8) press START
ATTENTION: do not touch the X and Y axes carriages and press
START.
9) press START
Fig. 151
1 - Test
2 - Machine ‘0’ points
1 - Cutting unit
2 - Reading unit
4 - Calibrations
5 - Maintenance
6 - Options
Install Z12 & Z13
templates.
See operating manual.
[ENTER]
Move X and Y axis
up until contact is made
See operating manual.
[START]
ERROR 10
no contact made.
See operating manual
ENTER
START
Pos. Photocells.
TZX=ON TZY=ON
See operating manual.
[START]
START
START