Silca Idea - Machine Zero Setting after Replacing the Photocells

Silca Idea
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright Silca 2004 131
Operating Manual - English IDEA
7.11.1 Machine zero setting after replacing the photocells
CUTTING UNIT
1) enter ‘Maintenance’ menu #5.
2) select ‘Machine zero points’ #2.
3)
select ‘Cutting unit’ #1
.
4) install the (Z13) template.
5) remove the cutter from the machine and install the (Z12)
template.
6) manually move the X and Y axes up until the templates
make contact.
7) lower the protective shield and press START.
ATTENTION: check that both the (Z13) and (Z12) templates make
perfect contact. If this does not occur the display will
show an error message.
8) press START
ATTENTION: do not touch the X and Y axes carriages and press
START.
9) press START
Fig. 151
1 - Test
2 - Machine ‘0’ points
1 - Cutting unit
2 - Reading unit
4 - Calibrations
5 - Maintenance
6 - Options
Install Z12 & Z13
templates.
See operating manual.
[ENTER]
Move X and Y axis
up until contact is made
See operating manual.
[START]
ERROR 10
no contact made.
See operating manual
ENTER
START
Pos. Photocells.
TZX=ON TZY=ON
See operating manual.
[START]
START
START