Argus Radar - Installation and service manual
988-10187-004 4.3
Video Test: On the PPI, only the video generated by the Training
function will be displayed, available in the ARPA and AIS Menu. It is
interesting to see it when using the Training function. In the picture, a
flashing cyan drawn cross is shown on the plot, which means that it is
the training target. The light brown rectangle is the tracking window,
normally not displayed.
Anti Sea Clutter: On the PPI, some concentric circles filled with different
levels of yellow colour will be displayed, showing the intensity of the
threshold of clutter suppression, according to the used shape.
In the zone of the strongest yellow, the anti sea clutter suppresses more video
than in the zone of the light brown. By increasing the STC control, the circles
will expand, indicating that the clutter suppression is moved out in range.
Tracking Window
By activating this control, it will be possible to see the windows where the
tracking is checking for targets. For more information regarding the tracking
windows, refer to the Video Selection section and see the Video Plot and Video
Test pictures.