© Jun 2022 7-8 TB24 Plus&26J Plus Maintenance Manual
REXROTH CONTROL SYSTEM
Standardization
1. On the ADVANCED SETTING interface, select
Standardization through
and , and press
to enter STANDARDIZATION interface.
Figure 7-14 STANDARDIZATION interface
2. Standard setting: On the STANDARDIZATION
interface, select Standard Set option through
,
change the value through
and , and press
and hold
for 3s to confirm the setting (there will
be the icon
before the selected option after
successful setting).
After changing the value to “0” and confirming
the setting, the program will not implement any
standard restrictions.
After changing the value to “1” and confirming
the setting, the program will implement the
restrictions of CE standard, and the icon of CE
standard ( ) will be displayed in the upper
right corner of the main interface.
After changing the value to “2” and confirming
the setting, the program will implement the
restrictions of ANSI standard, and the icon of
ANSI standard ( ) will be displayed in the
upper right corner of the main interface.
After changing the value to “3” and confirming
the setting, the program will implement the
restrictions of CSA standard, and the icon of
CSA standard ( ) will be displayed in the
upper right corner of the main interface.
After changing the value to “4” and confirming
the setting, the program will implement the
restrictions of AS standard, and the icon of AS
standard ( ) will be displayed in the upper
right corner of the main interface.
After changing the value to “5” and confirming
the setting, the program will implement the
restrictions of KCS standard, and the icon of
KCS standard ( ) will be displayed in the
upper right corner of the main interface.
After changing the value to “6” and confirming
the setting, the program will implement the
restrictions of JIS standard, and the icon of JIS
standard ) will be displayed in the upper
right corner of the main interface.
After changing the value to “7” and confirming
the setting, the program will implement the
restrictions of EAC standard, and the icon of
EAC standard ( ) will be displayed in the
upper right corner of the main interface.
After changing the value to “8” and confirming
the setting, the program will implement the
restrictions of UKC standard, and the icon of
UKC standard ( ) will be displayed in the
upper right corner of the main interface.
3. Overload limit setting: On the
STANDARDIZATION interface, select Overload
Limit option through
, and press and hold for
3s to confirm the setting. There will be the icon
before the selected option after successful setting,
and the KG icon ( ) will be displayed in the
upper right corner of the main interface.
4. Driving restriction (WCS) setting: On the
STANDARDIZATION interface, select Driving
Restriction (WCS) option through
, and press
and hold
for 3s to confirm the setting. There will
be the icon
before the selected option after
successful setting, and the DR icon ( ) will be
displayed in the upper right corner of the main
interface.
5. Interlock remove (drive/boom) setting: On the
STANDARDIZATION interface, select Interlock
Remove (Drive/Boom) option through
, and
press and hold
for 3s to confirm the setting.
There will be the icon
before the selected option
after successful setting, and the D/B icon ( )
will be displayed in the upper right corner of the
main interface.
6. To re-select the test option, press
to return to the
ADVANCED SETTING interface, re-enter the
STANDARDIZATION interface, and repeat the
above steps to select the desired option.
7. Press
successively to return to the main
interface, and power off the machine as required.
In KG mode, when the platform is overloaded, a
series of actions of the machine in operating
position will be restricted. The difference between
KG mode and non-KG mode can be found in the
Inspect Weighing System section in the
maintenance procedures of this Manual.
In DR mode, the driving function of the machine in
operating position will be restricted.
In D/B mode, driving function and boom actions can
be performed at the same time.
DR
CE
DR
ANSI
DR
CSA
DR
AS
DR
KCS
DR
JIS
DR
EAC
DR
UKC
DR
KG
DR
DR
DR
D/B