REXROTH CONTROL SYSTEM
2. On the PARAMETER SAVE interface, select the
desired function through
and , (there will be
the icon
before the selected option), press and
hold
for 3s to confirm the selection (there will be
the icon
before the selected option after
confirmation).
3. Press
successively to return to the main
interface, and power off the machine as required.
Notes:
Parameter (factory) set: used to save the current
parameters as factory parameters and the original
factory parameters will be overwritten. Please use
this function with caution.
Restore parameters (factory): used to restore the
current parameters to the factory parameters and
the current parameters will be overwritten. Please
use this function with caution.
Restore default: used to restore the current
parameters to the default parameters and the
current parameters will be restored. This function
shall be used with caution and generally only used
in the initial installation and debugging (requiring a
password to restore the default parameters).
Working time reset: used to clear the total working
time (after clearing, the total working time is about
36.5h). Please use this function with caution.
SYSTEM INFORMATION
On the main interface, press to enter SYSTEM INFO
interface.
Figure 7-20 SYSTEM INFO interface
Time setting
1. On the SYSTEM INFO interface, select Time
Setting through
and , and press to enter
TIME SETTING interface.
Figure 7-21 TIME SETTING interface
2. On the TIME SETTING interface, select the desired
setting option (the selected option will be flashing)
through
, change the value through and ,
and press
to confirm the changing (there will be
the icon
at the top of the interface).
3. Press
successively to return to the main
interface, and power off the machine as required.
Sensor information
The sensor information option is mainly used to
query the actual value of the sensor configured on
the machine, thus determining whether each sensor
is working normally.
The configuration of sensors is subject to the actual
machine configuration.
Figure 7-22 SENSOR INFO 1

Table of Contents