Maintenance and Inspection Schedule Section 1 – Scheduled Maintenance
1.2-6 About this Section
This section contains the maintenance and inspection
schedule that is to be performed.
References are made to the procedures in Section
5 that outline detailed step-by-step instructions for
checks and replacements.
Service Bulletins
Before performing any scheduled maintenance
inspection procedure, refer to service bulletins found
in our web site: www.skyjack.com for updates related
to service and maintenance of this MEWP.
Maintenance and Inspection
Death or injury can result if the MEWP is not kept in
good working order. Inspection and maintenance
should be performed by competent personnel who
are trained and qualified on mantenance of this
MEWP.
WARNING
Failure to perform each procedure as presented
and scheduled may cause death, serious injury or
substantial damage.
NOTE
Preventive maintenance is the easiest and least
expensive type of maintenance.
Unless otherwise specified, perform each
maintenance procedure with the MEWP in the
following configuration:
MEWP parked on a flat and level surface
Disconnect the batteries by disconnecting the
main power connectors.
Repair any damaged or malfunction
components before operating MEWP.
Keep records on all inspections.
Maintenance Instructions
This manual consists of four schedules to be done
for maintaining on an MEWP. Inspection schedule
frequency is shown below:
Task Frequency
PDI/Frequent B
Perform PDI prior to each
delivery, or Frequent
Inspection every 200 days
or 200 hours.
Annual C
Perform Scheduled
Maintenance Inspections
every year.
Additional *
Perform at time sensitive
maintenance intervals
Make copies of the maintenance and inspection
checklist to be used for each inspection.
Check the schedule on the checklist for the type
of inspection to be performed.
Place a check in the appropriate box after the
item meets the inspection requirements.
Use the maintenance and inspection checklist
and step-by-step procedures in Section 1 to
perform these inspections.
If any inspection receives a fail,write the issue
in the comments section. Tag and remove the
MEWP from service.
If any MEWP component(s) has been repaired,
an inspection must be performed again before
removing the tag.
Legend
Pass P
Not applicable N/A

Table of Contents

Other manuals for Skyjack SJ16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ16 and is the answer not in the manual?

Skyjack SJ16 Specifications

General IconGeneral
Gradeability25%
Drive Motor24V DC
Max Gradeability25%
Platform Height16 ft
Lift Capacity500 lbs
Machine Width0.76 m
Overall Width0.76 m
Drive Speed (Stowed)4.8 km/h
Drive Speed (Raised)0.8 km/h
Turning Radius (Inside)0 in
Power Source24V DC Electric