Section 5 – Procedures Battery Maintenance
5.7 Battery Maintenance
This section provides the operator with procedures
on how to service and charge the battery. This also
provides the charger operation instructions.
Servicing the battery
WARNING
Explosion hazard. Keep flames and
sparks away. Do not smoke near
batteries. Battery acid releases
explosive gas while charging. Charge
batteries in a well-ventilated area.
WARNING
Battery acid is extremely corrosive – wear proper
eye and facial protection as well as appropriate
protective clothing. If contact occurs, immediately
flush with cold water and seek medical attention.
1. Turn the main power disconnect switch to the off
position.
2. Check the battery case for damage.
3. Check the battery fluid level in each battery. If the
plates are not covered by at least 13 mm (1/2 in)
of solution, add distilled or demineralized water.
4. Make sure all the battery connections are tight.
NOTE
Do not use any batteries other than the flooded
lead-acid batteries of the proper Ah rating.
WARNING
Use the original or equivalent to the original parts
and components for the MEWP.
5.7-1 Charger Maintenance
1
2b
3
2a
4
5
6
No.
Indicator
type
State
Description/action
required
1
AC
power
Blue
Battery charger is
connected to the AC
power.
2a
Battery
charging
<80%
Flashing
green
Low charge— continue
charging.
Solid
green
High charge—
continue charging.
2b
Battery
charging
>80%
Flashing
green
High charge— can
discontinue charging.
Solid
green
Charge complete—
discontinue charging.
3
Fault/
error
Solid red
Charger fault—refer to
the service manual.
Flashing
amber
Error encountered—
refer to the service
manual.
4
Charging
output
Solid
yellow
Charger output is
active.
5
Charge
profile/
error
display
Current
algorithm
or fault/
error code
N/A.
6
Select
charge
profile
Current
charging
algorithm
N/A.

Table of Contents

Other manuals for Skyjack SJ16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ16 and is the answer not in the manual?

Skyjack SJ16 Specifications

General IconGeneral
Gradeability25%
Drive Motor24V DC
Max Gradeability25%
Platform Height16 ft
Lift Capacity500 lbs
Machine Width0.76 m
Overall Width0.76 m
Drive Speed (Stowed)4.8 km/h
Drive Speed (Raised)0.8 km/h
Turning Radius (Inside)0 in
Power Source24V DC Electric

Related product manuals