– 7 –
[Description on Self-diagnosis Display]
Note : The “Self-diagnosis” data is backed up by the coin
lithiumbattery. The data will be lost and initialized when
the coin lithium battery is removed.
Display Code
C:32:01
C:13:01
E:91:01
*1
*1
Countermeasure
Change the disk and turn off the main
power then back on.
Replace the floppy disk.
Format the floppy disk with the MVC-
FD83/FD88.
Cause
Defective floppy disk.
The type of floppy disk that cannot be
used by this machine, is inserted.
(Such as 2DD)
Data is damaged.
Unformatted disk is inserted.
Abnormality when flash is being
charged.
Caution Display During Error
DRIVE ERROR
DISK ERROR
Flash LED
Flash display
Flashing at 3.2 Hz
Note : The error code is cleared if the battery is removed, except defective flash.
*1 : The error display is given in two ways.
*2 : When the flash charging failed, Page:D, Address:C7, Data:04 are written.
After repair, be sure to write Page:D, Address:C7, Data:00.
[Power supplying Method]
Use the AC power adaptor (BC-V615) when supplying the power to this set.
C:63:00
E:61:00
C:63:10
E:61:10
Repair by service engineers only.
When failed in the focus initialization.
When failed in the zoom initialization.