Personnel:
n
Service personnel
Replace hydraulic hoses every 6 years (according to date of manu‐
facture).
ð
Only use hydraulic hoses approved by the manufacturer, see
spare-parts list.
1.
Check the hydraulic connections for the following when pressure‐
less:
n Damage
n Leakages
ð
Repair damaged or leaking hydraulic connections imme‐
diately or have them replaced.
2. Connect the hydraulic connections pressureless.
3.
Check leak tightness of the hydraulic connections under pressure.
ð
Repair damaged or leaking hydraulic connections imme‐
diately or have them replaced.
9.2.6 Electrics
Perform visual inspection of the connector plugs and cables.
n Watch for bent or broken contact pins in the plugs.
n Watch for exposed places in cables.
ð
Repair damaged connector plugs or cable connections
immediately or have them replaced.
Replacing hydraulic hoses
Check hydraulic connections
Checking connector plugs and lines
Maintenance and repair work