2–9
Chapter 2: Menu Operations
Selecting And Running a Current Calibration Routine
Step 1. Take the printer offline and place it in Tech Access Mode.
Step 2. Access the TEST Menu.
Step 3. Depress the Forms/1 key to access the TEST Menu categories, then scroll ( Key)
until the Diag Category is displayed.
Step 4. Depress the CPI/2 key to access the Diag Category parameters, then scroll ( Key)
until the Prntcal Parameter is displayed.
Step 5. Depress the LPI/3 key to access the Prntcal selections, then scroll ( Key) until
Current is displayed.
Step 6. Looking at the Control Panel display, depress the ENTER key. The printer firm-
ware performs a calibration routine and the new value will be displayed. (Values
will vary from printer to printer). Once the value is displayed you have completed
the routine.
Selecting And Running a Paper Out Calibration Routine
Step 1. Take the printer offline and place it in Tech Access Mode.
Step 2. Access the TEST Menu.
Step 3. Depress the Forms/1 key to access the TEST Menu categories, then scroll ( Key)
until the Diag Category is displayed.
Step 4. Depress the CPI/2 key to access the Diag Category parameters, then scroll ( Key)
until the Printcal Parameter is displayed.
Step 5. Depress the LPI/3 key to access the Printcal selections, then scroll ( Key) until
PapOut is displayed.
Step 6. Depress the ENTER key to begin the first part of the Paper Out Calibration
Routine. Follow steps on display.
When removing paper, the tractor door must be closed to ensure proper reading.