6.4.2.13 DATA READING IN THE LOW-KIT MEMORY
Name  Notes


memory
 @READREG# -
 
Tab. 25
6.4.2.14 LIFE-DATA RESET
Name  Notes
 

 @RESETSTAT#
 LIFE-DATA ERASED or
ERROR
LIFE-DATA ERASED if reset was
successful.
ERROR if reset was not successful.
Tab. 26
6.4.2.15 
Name  Notes
 
error log
info
 @RERRORLOG# where
0 ≤ N ≥ 4 (High-kit)
0 ≤ N ≥ 9 (Low-kit)
< n_error>= number of errors
saved
<error_code>= error code
<time>=date error formatted as
follows: dd-MM-yy hh:mm
where
dd= day
MM= month
yyyy= year
hh =hour
mm= minutes
 < n_error0> <error_code0>
<time0>
...
<n_errorN> <error_codeN>
<timeN>
Tab. 27
6.4.2.16 RESET ERROR LOG (HIGH-KIT)
TECHNOGYM ELLIPTICAL Technical Service Guide