6.9 BRAKE BOARD ERROR CODE LIST
ERROR
CODE
ERROR DESCRIPTION SOLUTION
E1 Electrical Overtemperature: This error
occurs when the internal temperature
sensor reaches a specic value. In this
case the board passes into fault status
and the error is recorded in the error log.
Swicth OFF the equipment and keep
it OFF to have the cool down of the
electronics. If the error appears when
the brake board is cold, replace it.
E2 Brake kit overcurrent: when costant
training session is selected, if the braking
current value reaches 150% of the
max value in the brake table, the Error
appears.
Switch OFF and ON the equipment. If
the Error appears again without starting
the exercise, replace the brake
board.
E4 Eeprom Fault: wrong brake table. Reload the brake table. If the
problem persists, replace the brake
board.
E32 CRC error on the braking table: this oc-
curs when the installed braking table has
an erroneous CRC.
Reload the brake table. If the problem
persists, replace the brake board.
Tab. 38
6.10 ERROR CODE LIST (HARDWARE FAULT)
ERROR CODE ERROR DESCRIPTION SOLUTION
HF: [from 401 to 408]
(405 not included)
Eeprom Fault Replace the display
HF 500 Low kit error Replace the low kit
Tab. 39
For details regarding the procedure to follow when replacing components, see § “6.1 Procedure to
follow when replacing components”.
Equipment testing after the intervention of technical service: see § “6.2 Equipment testing after the