EasyManua.ls Logo

TECO JSDG2S Series - Page 105

TECO JSDG2S Series
718 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-19
dn-07 (Automatic adjustment of external analog voltage offset )
JSDG2S-E(L) does not have
this function
When the External Torque or Speed Analog Command Input is 0V, the Motor may still rotate
slowly, the User can use
dn-07
to automatically adjust and correct the Analog Command Offset, the
External Voltage Offset can be checked with
Un-09
and
Un-11
after automatically adjusted, and the
Automatic Adjustment Procedure is described as follows:
Steps
Operation
Key
LED Display Screen
after Operation
Description
1
Please confirm the status is Servo off before adjustment; Input 0V voltage command
from the supervisory controller or external loop to analog command connect SIC
(CN1-26) & TIC (CN-1-27).
2
Turn on
Power
When the power is turned on, Enter the
Status
Display Screen
.
3
Press MODE Key 2 times to enter
Diagnostic
Parameters
.
4
Press UP Key 6 times to select
dn-07
Item.
5
Press and hold the ENTER Key for 2 seconds, enter
dn-07
setting screen.
6
Press UP Key 1 time, the value of 1 represents the
Offset Automatic Adjustment to be executed.
7
Press and hold the ENTER for 2 seconds until -SET-
appears 1 time then jump back to the current
parameter item selection screen immediately, the
Offset Automatic Adjustment
Sn217 (Analog Speed
Command Offset Adjustment)
and
Tn104 (Analog
Torque Command Offset Adjustment)
settings are
completed at this time.