5-42
Parameters Description Setting range Unit
Take effect
method
Related
chapter
Cn001
Control mode selection
6: Internal position
control
-- Power reset
5-4
Cn010
First stage CCW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn011
First stage CW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn056
Second stage CCW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn057
Second stage CW direction torque
command limit value
0 ~ 300 %
Take effect
after setting
5-4-8
Cn058
Delay time for the first stage torque
limit to switch to the second stage
torque limit
0 ~ 32767 4ms
Take effect
after setting
5-4-8
Tn103
Analog torque command proportioner 0 ~ 600
%/10V
Take effect
after setting
5-4-8
Tn104
Analog torque command offset
adjustment
-2500 ~ 2500
mV
Take effect
after setting
5-4-8
Tn116 Analog torque command filter 0 ~ 5000 Hz
Take effect
after setting
5-4-8
Sn201
Internal speed command 1
-1.5*rated rotation
speed~1.5*rated
rotation speed
rpm
Take effect
after setting
5-4-9
Pn301.2
Drive prohibit command reception
selection
0 ~ 1
-- Power reset
5-4-1
Pn302
Electronic gear ratio numerator 1 1 ~ 536870912
--
Take effect
after setting
5-4-3
Pn303
Electronic gear ratio numerator 2 1 ~ 536870912
--
Take effect
after setting
5-4-3
Pn304
Electronic gear ratio numerator 3 1 ~536870912
--
Take effect
after setting
5-4-3
Pn305
Electronic gear ratio numerator 4 1 ~ 536870912
--
Take effect
after setting
5-4-3
Pn306
Electronic gear ratio denominator 1 ~ 536870912
-- Power reset
5-4-3
Pn307
Positioning complete determination
value
0 ~ 41943040
pulse
Take effect
after setting
5-4-9
Pn313
Internal/external position command
one-time smooth
acceleration/deceleration time
constan
t
0 ~ 10000
ms Power reset
5-4-4
Pn314.0
Rotation direction selection (looking
from the load of the motor)
0 ~ 1
-- Power reset
5-4-5
Pn315.0
Pulse wave error amount clear mode 0 ~ 2
--
Take effect
after setting
5-4-6

Table of Contents