5-162
EC917 Maximum proceeding distance of E-Cam rotary cut auxiliary axle
Initial Value Unit Setting Range Effective RS-485 Address
10000 0.1mm 1 ~ 50000
Effective after Confirmed
0811H
Setting Description: Maximum axle moving distance. This parameter is the maximum movable
distance of auxiliary axle screw and will determine if the range is exceeded in
combination of other parameters.
EC918 Average proceeding speed of E-Cam rotary cut main axle
Initial Value Unit Setting Range Effective RS-485 Address
100 rpm 1 ~ 1000
Effective after Confirmed
0812H
Setting Description: Average moving speed of the main axle. The user must fill in the correct average
speed of the main axle so that ECA14 can have correct time.
EC920 Maximum return speed of E-Cam rotary cut
Initial Value Unit Setting Range Effective RS-485 Address
0 rpm 0 ~ 3000
Effective after Confirmed
081CH
Setting Description: Set the maximum return speed of rotary cut. The program will run internal
calculation by itself when the setting is 0.
EC921 Acceleration/Deceleration time of E-Cam rotary cut
Initial Value Unit Setting Range Effective RS-485 Address
0 ms 0 ~ 50000
Effective after Confirmed
081DH
Setting Description: Set the acceleration/deceleration time of rotary cut. The program will run internal