5-163
EC922 Enable E-Cam parameter change write-in
Initial Value Unit Setting Range Effective RS-485 Address
0 - 0 ~ 1
Effective after Confirmed
081EH
Setting Description: Set this parameter as 1 when changing the parameter to enable parameter change.
EC923 E-Cam parameter fine-tune factor
Initial Value Unit Setting Range Effective RS-485 Address
10000 0.01 0 ~ 65535
Effective after Confirmed
081FH
Setting Description: Fine-tune the cutting length to correct machine error.
EC924.0 E-Cam rotary cut return origin return function
Initial Value Unit Setting Range Effective RS-485 Address
0 - 0 ~ 1
Effective after Confirmed
0820H
Setting Description:
Setting Description
0 Original curve
1 Return to Origin
Pn349 Full-closed loop operation direction setting
Initial Value Unit Setting Range Effective RS-485
0 -- 0 ~ 1 Power Re-set 033CH
Setting Description: It is necessary to consider main axle feedback direction when choosing the
physical main axle. AL.023 will occur when the direction is incorrect.
Setting Description
0 Phase A leading phase B
1 Phase B leading phase A