7-92
Pn349 Full-closed loop operation direction setting
【
5-6-13
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
★
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
033CH 2331H 2331H O O -- -- --
Setting Description:
Setting Description
0 Phase A leading phase B
1 Phase B leading phase A
Pn350.0 Enable gantry synchronization function
【
5-6-16
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
★
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
033DH -- -- O O -- -- --
Setting Description:
Setting Description
0 Close
1 Activate
Attention! Gantry synchronization function CANNOT be activated with full-closed loop
function at the same time. If both functions are turned on at the same time, they will be shut
down forcibly.
Pn350.1 Gantry synchronization triggered to enable asynchronous function
【
5-6-16
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
★
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
033DH -- -- O O -- -- --
Setting Description:
Setting Description
0 Close
1 Activate