Appendix B: TPP0051, TPP0101 and TPP0201 Series 10X Passive Probes Information
Table 19: Certi
cations and compliances
Characteristics Description
EC Declaration of
Conformity
Compliance was demonstrated to the following speci cation as listed
in the Ofcial Journal of the European Communities:
Low Voltage D
irective 2006/95/EC:
EN61010-031: 2002
Safety Standards
UL61010-03
1;2007
CAN/CSA C22.2 No. 61010-031-07
IEC61010-031; IEC 61010-031/A1:2008
Category Examples of Products in this Category
CAT III Distribution-level mains, xed installation
CAT II
Local-level mains, appliances, portable equipment
Measurement
Category
Descripti
ons
CAT I Circuits not directly connected to mains.
Pollution Degree 2 Do not operate in environments where cond–
uctive pollutants may be present (as de ned in IEC 61010-1). Rated
for indo
or use only.
Equipment Recycling. This product complies with the European Union’s
requirements according to Directive 2002/96/EC on waste electrical and
electronic equipment (WEEE). For more in formation about recycling options,
check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Safety Summary
Review the following safety precautions to avoid injury and prevent dama ge t o
this product or any products connected to it. To avoid potential hazards, use this
product only as specied. Using the probe or accessories in a manner not s pecied
couldresultinashockorre ha zard.
To Avoid Fire or Personal
Injury
Ground-Referenced Oscilloscope Use. Do not oat the reference lead of this
probe when using with ground referenced oscilloscopes (for example, TBS series
oscilloscopes). The reference lead must be connected to earth potential (0 V).
Connect and Disconnect Properly. Connect the probe output to the measurement
instrument before connecting the probe to the circuit under test. Disconnect
the probe input and the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Avoid Electric Shock. Do not connect or disconnect probes or test leads while
they are connected to a voltage source.
Observe All Terminal Ratings. To avoid re or shock hazard, observe all ratings
and markings on the product. Consult the product manual for further ratings
information before making connections to the product.
118 TBS1000B and TBS1000B-EDU Series Oscilloscopes User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TB1052B-EDU and is the answer not in the manual?

Tektronix TB1052B-EDU Specifications

General IconGeneral
BrandTektronix
ModelTB1052B-EDU
CategoryTest Equipment
LanguageEnglish

Related product manuals