Telephone Line Emulator User’s Manual
40-400-00020, Rev. M
39
International Software Module (TLE-INTL)
The TLE International Software Module includes 11 preset country configurations and 5
settings preset to North America. An additional 11 countries are also included with the
software and are installed when the ‘Sample Configuration Files’ option is selected during
the software installation process.
The TLE-INTL Software Module is an upgrade to the TLE Base unit which provides certain
default country specific operational characteristics. These include: line impedance, ringing
cadence, ringing voltage, ringing frequency, call progress levels, call progress
frequencies, call progress cadences and line reversal. When this module is resident, the
TLE stores the programming of up to 16 configurations, versus only two configurations in
the TLE Base unit.
The default countries supported (one per configuration) are: Australia, Brazil, France,
Germany, Ireland, Japan, Korea, Netherlands, Singapore, Sweden, United Kingdom, and
US/Canada. The remaining four configurations are configured for US/Canada. The
additional country configurations available are Austria, Belgium, China, Denmark, Finland,
Greece, India, Italy, Norway, Spain and Switzerland.
This module is compatible with all features of the base unit, and may be co-resident with
the TLE-ADV Software Module.
Note: The TLE-INTL Software Module allows Caller ID to be enabled for other countries, but it
conforms to the Bellcore (USA/Canada) standards to support other Caller ID standards.
The TLE-ICID Software Module is available as an upgrade to the TLE-INTL.
Rotary Dialing
The TLE rotary dial algorithm will allow the detection of the two most common rotary dial
specifications:
1. 40 mS/60 mS make/break ratio (U.S., Germany, Sweden, etc.)
2. 33 mS/67 mS make/break ratio (U.K., France, Ireland, etc.)
The digit translation will follow the U.S. standard (digit 1 = 1 pulse, digit 2 = 2 pulses, etc.)
for all countries.
Note: This upgrade requires a software key that is generated by Teltone when the user supplies
the TLE Unit ID and the TLE-INTL serial number to Teltone. The instructions are included
on the Application Guide with the upgrade module.