Telephone Line Emulator User’s Manual
40-400-00020, Rev. M
47
Austria Defaults
To make the settings for this country available, follow the instructions in
“Importing Additional Countries” on page 41.
Description Frequency (Hz) Cadence*1 Signal level
Dial Tone 420 // 450 Continuous -26dBm to -16dBm
Recall Dial Tone 420 Continuous -26dBm to -16dBm
Special Dial Tone 380 + 420 Continuous -26dBm to -16dBm
Ringing Tone 420 // 450 1.0(on)-5.0(off) -43dBm to -
6.5dBm
Ringing Signal 50 1.0(on)-5.0(off) 26Vac to 66Vac
Busy Tone I 420 // 450 0.4(on)-0.4(off) -43dBm to -
6.5dBm
Busy Tone II 420 // 450 0.3(on)-0.3(off) -43dBm to -
6.5dBm
Congestion Tone 420 // 450 0.2(on)-0.2(off) -43dBm to -16dBm
SIT Tones 950 0.33(on) -43dBm to -9dBm
1400 0.33(on) -43dBm to -9dBm
1800 0.33(on)-1.0(off) -43dBm to -9dBm
Call Waiting Tone 420 0.04(on)-1.95(off) -36dBm to -10dBm
Metering Tones 12 000 0.05(on)-0.05(off) 50mV to 2.5V
Impedance: 600 Ω
fff//fff is defined because some exchanges use the first frequency and is the default, and
other exchanges use the second frequency.