Telephone Line Emulator User’s Manual
40-400-00020, Rev. M
51
Denmark Defaults
To make the settings for this country available, follow the instructions in
“Importing Additional Countries” on page 41.
Description Frequency (Hz) Cadence *1 Signal level
Dial Tone 425 Continuous -26dBm to -6.5dBm
Special Dial Tone 425 with Continuous -21dBm to -6.5dBm
375 0.12(on)-1.0(off) -23dBm to -8.5dBm
Ringing Tone I 425 0.75(on)-7.5(off) -43dBm to -6.5dBm
Ringing Tone II 425 1.0(on)-4.0(off) -43dBm to -6.5dBm
Ringing Signal I 25 0.75(on)-7.5(off) 40Vac to 120Vac
Ringing Signal II 25 1.0(on)-4.0(off) 40Vac to 120Vac
Busy Tone I 425 0.45(on)-0.45(off) -43dBm to -6.5dBm
Busy Tone II 425 0.25(on)-0.25(off) -43dBm to -6.5dBm
Congestion Tone I 425 0.45(on)-0.45(off) -43dBm to -6.5dBm
Congestion Tone II 425 0.25(on)-0.25(off) -43dBm to -6.5dBm
SIT Tones 950 0.33(on)-[<0.03](off) 43dBm to -6.5dBm-
1400 0.33(on)-[<0.03](off) -43dBm to -6.5dBm
1800 0.33(on)-1.0(off) -43dBm to -6.5dBm
Metering Tones 12 000 [.075 to 0.12](on)-
[>0.05](off)
-27dBm to +15dBm
Impedance: 600 Ω
fff//fff is defined because some exchanges use the first frequency and is the default, and
other exchanges use the second frequency.