Telephone Line Emulator User’s Manual
40-400-00020, Rev. M 58
Italy Defaults
To make the settings for this country available, follow the instructions in
“Importing Additional Countries” on page 41.
Description Frequency (Hz) Cadence *1 Signal level
Dial Tone 425 0.2(on)-0.2(off)-
0.6(on)-1.0(off)
-25dBm to -6dBm
Special Dial Tone 425 Continuous -25dBm to -6dBm
Ringing Tone 425 1.0(on)-4.0(off) -43dBm to -6dBm
Ringing Signal 35 1.0(on)-4.0(off) 26Vac to 80Vac
Busy Tone 425 0.5(on)-0.5(off) -43dBm to -6dBm
Reorder Tone 425 0.2(on)-0.2(off) -43dBm to -6dBm
SIT Tones 950 0.33(on)-
[<0.020](off)
-32dBm to -
15dBm
1400 0.33(on)-
[<0.020](off)
-32dBm to -
15dBm
1800 0.33(on)-1.0(off) -32dBm to -
15dBm
Metering Tones 12 000 0.125(on)-0.15(off) 65mV to 2.4V
Impedance: 600 Ω