Telephone Line Emulator User’s Manual
40-400-00020, Rev. M
55
Greece Defaults
To make the settings for this country available, follow the instructions in
“Importing Additional Countries” on page 41.
Description Frequency (Hz) Cadence Signal level
Dial Tone 425//450 0.2(on)-0.3(off)-
0.7(on)-0.8(off)
-25dBm to -4dBm
Ringing Tone 425//450 1(on)-4(off)
Ringing Signal 16 to 50 1(on)-4(off) 25 to 90Vac
Busy Tone 425//450 0.3(on)-0.3(off)
Reorder Tone 425 0.15(on)-0.15(off)
or 0.3(on)-0.3(off)
SIT Tones/N.U.T. 950 0.33(on)
1450 0.33(on)
1800 0.33(on)-1(off)
Call Waiting Tone 425 0.3(on)-10(off)
(twice)
Metering Tones 16 000 0.05(on)-0.09(off) -18dBm to +18dBm
Impedance: 600 Ω
fff//fff is defined because some exchanges use the first frequency and is the default, and
other exchanges use the second frequency.