Telephone Line Emulator User’s Manual
40-400-00020, Rev. M
93
Timers
Ring end to FSK 550 mS
DTMF/FSK end to ring start 200 mS
On-hook channel Seizure 250 mS
On-hook Mark length 150 mS
Off-hook Mark length 67 mS
Ring burst 250 mS
Ring Cadence Group 1 1.5 sec on/3.5 sec off
Ring Cadence Group 2 .8 sec on/.4 sec off/.8 sec on/ 4 sec off
Ring Cadence Group 3 1 sec on/1 sec off/1 sec on/ 3 sec off
User message #1 Set to: 13H,2;network status = 2 messages
User message #2 Set to: 13H,3;network status = 3 messages
User message #3 Set to: 13H,4;network status = 4 messages