EasyManua.ls Logo

Texecom Premier Elite 24

Texecom Premier Elite 24
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UDL & Digi Options Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual
104 INS176-9
No Type Event Reporting Group Contact ID SIA ID
75 NVM Defaults Loaded Alarm Not Reported - - Zone No
Restore Not Reported - - Zone No
76 First Knock Alarm Not Reported - - -
Restore Not Reported - - -
77 Door Access Alarm Not Reported - - -
Restore Not Reported - - -
78 Part Arm 1 Alarm Not Reported - - -
Restore Close 401 CL User No
79 Part Arm 2 Alarm Not Reported - - -
Restore Close 401 CL User No
80 Part Arm 3 Alarm Not Reported - - -
Restore Close 401 CL User No
81 Auto Arming Start Alarm Not Reported - - -
Restore Close 401 CL 000
82 Confirmed Alarm Alarm Alarm 139 BV Zone No
Restore Not Reported - - -
83 Prox TAG Alarm Not Reported - - -
Restore Not Reported - - -
84 Access Code Changed/Deleted Alarm Not Reported - - -
Restore Not Reported - - -
85 Arm Failed Alarm Not Reported - - -
Restore Not Reported - - -
86 Log Cleared Alarm Maintenance - - -
Restore Not Reported 401 CL 000
87 iD Loop Shorted Alarm Tamper 145 TA 000
Restore Restore 145 TR -
88 Communication Port Alarm Maintenance - - 000
Restore Restore - - 000
89 TAG System Exit (Batt. OK) Alarm Not Reported - - Zone No
Restore Not Reported - - Zone No
90 TAG System Exit (Batt. LOW) Alarm Not Reported - - -
Restore Not Reported - - -
91 TAG System Entry (Batt. OK) Alarm Not Reported - - -
Restore Not Reported - - -
92 TAG System Entry (Batt. LOW) Alarm Not Reported - - -
Restore Not Reported - - -
93 Microphone Activated Alarm Not Reported - - -
Restore Not Reported - - -
94 AV Cleared Down Alarm Not Reported - - -
Restore Not Reported - - -
95 Monitored Alarm Alarm Alarm 220 BA Zone No
Restore Restore 220 BH Zone No
96 Expander Low Voltage Alarm Maintenance 143 ET Device No
Restore Restore 143 ER Device No
97 Supervision Fault Alarm Maintenance 355 UT Zone No
Restore Restore 355 UJ Zone No
98 PA From Remote FOB Alarm Priority Alarm 121 121 Zone No
Restore Restore HA HH Zone No
99 RF Device Low Battery Alarm Maintenance 384 XT Zone/User No
Restore Restore 384 XR Zone/User No
100 Site Data Changed Alarm Maintenance - - -
Restore Restore - - -
101 Radio Jamming Alarm Maintenance 344 XQ 000
Restore Restore 344 - 000