Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual Global Options
INS176-9 63
25 - Keypad PA Delay
When keypad ‘option 6’ is programmed as ‘PA Delayed’ (see page
73 for details), and a keypad PA alarm (1 & 3) is activated, this timer
starts. If a User code is entered before this timer expires, no PA alarm
will occur. However, if a User code is not entered before this timer
expires, a PA alarm will occur.
26 - Confirmation Dly
When an Intruder alarm occurs, this timer starts. If a second
(different) zone is activated within this time window, the ‘Confirmed’
output will activate. When this timer
expires, the ‘Confirmed’ output will no longer activate.
27 - Warning Delay
When a Custom zone with the ‘Warning Req’ attribute (see page 52
for details) activates, this timer is started. If the zone is still active
when this timer expires a warning tone or alarm will occur and the
Warning Output (see page 80 for details) will activate.
28 - Keypad Lock Time
When code tampers are programmed to lockout the keypad (see
page 64 for details), the keypad will lock out for the duration of this
timer.
29 - Eng. log off Dly
This timer starts when an Engineers code is entered. When the timer
expires the engineer is automatically logged out of engineer’s mode. This
timer is suspended if there are tamper faults on the system allowing the
engineer to remain in engineer’s mode indefinitely whilst on site.
30 - Fire Bell Delay
This timer starts when a fire alarm is generated in a particular area.
When the timer expires sounders are activated in ALL areas.
31 - Forced Entry Dly
When a zone with the ‘Guard’ attribute (see page 51 for details)
activates, this timer is started. For the duration of this timer, any
‘Entry/Exit 1 or 2’ zone with the ‘Entry/Exit 2’ attribute (see page 51
for details) will become a ‘Guard’ zone. When this timer expires, the
‘Entry/Exit 1 or 2’ zone will revert back to its normal mode of
operation.
32 - Supervision Time
This timer controls the frequency at which the RadioPLUS detectors
are required to report in to the control panel.
33 - Poll IP Every
This timer controls the frequency that the ComIP Polls the ARC.
System Config.
E o elec:-
loal pions
loal pions
yse ies
loal pions
yse onig
onigaion 
o ell e ail
Press NO to cha nge
the config. option
onigaion 
 is Unloced
E nter a configura tion
number or us e the
S C R OL L key to se arc h
e.g. 09 = NVM Unlocked
onigaion 
 is oced
y
1
y
n
y
These options control how various system functions work.
00 - No Bell Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Strobe’
output will activate.
Bell on Arm Fail
If an area fails to arm, an Internal alarm will occur and the ‘Bell’
output will activate for 10 seconds.
The ‘Strobe’ output will also activate for 5 seconds to indicate
that the system has armed/disarmed.
01 - Bell is an SAB
The ‘Bell’ output on the control panel applies 0V when active.
Bell is an SCB
The ‘Bell' output on the control panel removes 0V when active.
02 - Clock is 24Hr
The system time is displayed in the 24-Hour format.
Clock is 12Hr (Default)
The system time is displayed in the 12-Hour format.
03 - Auto BST/GMT
The system clock will adjust itself at the beginning and the end of the
summer (the clock will automatically gain 1Hr on the last Sunday in
March and lose 1Hr on the last Sunday in October.
Manual BST/GMT
The system clock will not adjust itself at the beginning and the end of
the summer (the clock will have to be adjusted manually).
04 - View Armed Areas
When the system is part armed, the areas that are armed are
displayed and alarm information is displayed before a valid User
code is entered.
Hide Armed Areas
When the system is part armed, the areas that are armed are not
displayed and alarm information is only displayed after a valid User
code has been entered.