EasyManua.ls Logo

Texecom Premier Elite 24

Texecom Premier Elite 24
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual Engineer Utilities
INS176-9 113
Event Log Descriptions
Log Event Description
### ARM FAILED An exit fault from Zone ### has caused the system to fail to arm
### Flt Alarm Zone ### has detected a Fault condition
### Mask Alarm Zone ### has detected a Mask condition
### Test Failed Zone ### has activated whilst it has been on soak test
### Tested OK Zone ### has activated during the walk test
#,# RESET AREAS - Area have been reset using keypad #,# following an Intruder alarm
AC Off Alarm The control panel has detected an AC Mains failure
ALARM ABORT
An Open After Alarm-Abort has occurred for area ?
ALARM Active
An Intruder alarm signal has been activated for area ?
Anti-Code Reset A reset has been performed using the Anti-code reset procedure
AREA Armed Area ? has been armed
AREA Disarmed Area ? has been disarmed
ARMED WITH L/F The system has been armed with a Line Fault condition present
ARMING FAILED A Exit Error-Arm Fail has occurred on area ?
ARMING SUITE # Area Arm Suite # was used to arm the system
ATS FAILED The Communicator has failed to report to the Alarm Receiving Centre
ATS FLT Alarm There is a problem with the telephone line
AUTO TEST CALL
An Automatic test call has been initiated
AUX #,# Tamper An Auxiliary Tamper input from device #,# has been activated
AV CLEARED by ## The Audio Verification unit has been cleared down by user ##
BELL #,# Tamper A Bell Tamper input from device #,# has been activated
BELL Active The Bell output has been activated for area ?
BELL FUSE Alarm The control panel Bell Fuse has failed
BOX LID Tamper The control panel lid has been removed causing a Tamper alarm
CHARGER FAULT Battery Charge Current has Failed
CIE Reset The internal processor has failed its self checks.
CODE #,# Tamper
Too many invalid key presses have caused a tamper alarm from keypad #,#
Com??? Line Fault The Com300, 2400 or ISDN has detected a line fault
COM PORT Alarm A com port has generated an alarm
CONFIRMED ALARM Two or more detectors have activated, resulting in a confirmed alarm condition
CONFIRMED PA Two or more PA zones have activated, resulting in a confirmed PA alarm condition
CONFIRMED INTRUDER Two or more detectors have activated, resulting in a confirmed Intruder condition
CORRUPT EVENT No event has been stored in memory
CROSS ### Alarm A Verified Cross Zone (Beam Pair) Alarm has occurred from zone ###
DATA CHANGED Programming data has been changed
DATE CHANGED
The control panel Time has been changed
DEFAULTS LOADED
The factory default values have been loaded into memory
DEFERRED The arming mode was deferred for area ?
DOOR #,# Door #,# has been opened by a user with Door Control
DOWNLOAD START An Upload/Download has been initiated
DOWNLOAD END The Upload/Download has finished
DURESS User ## has entered a Duress Code at a keypad
Engineer Reset A reset has been performed using an Engineers code
ENTRY Area ## The Entry mode has been started for area ?
EXIT Area ## The Exit mode has been started for area ?
EXP #,# Reset
A reset has been performed using the input on expander #,# (programmed as reset)
EXP #,# Line Fault The Input on expander #,# (programmed as line fault) has been activated
EXP #,# LOST Expander ## has been lost from the network
EXP #,# Tamper The cover of expander #,# has been removed
EXP ## Low Voltage Expander #,# has detected that its supply voltage is low
F_PA ## A Panic Alarm from a Radio FOB has been generated
Fault Override The system has been armed with a Fault condition present by a user
FIRE ### Active Zone ### (programmed as Fire Alarm) has caused an alarm
FIRE ### Tamper
Zone ### (programmed as Fire Alarm) has caused an Tamper alarm
FIRST KNOCK ###
Zone ### (which is programmed as double knock) has activated for the first time
FUSE #,# Alarm The Auxiliary 12V Fuse in device #,# has failed
GSM MODULE LOST The GSM Module has lost communications with the control panel
iD Loop# Tamper There is a short circuit on iD loop # on the iD expander
Key switch Reset A reset has been performed using a key switch
KSW ### Disarmed A Keyswitch zone type has been activated (zone number ###)
LOG ALERT 80% of the Event Log has filled (since the last Upload/Download)
LOG CLEARED The event log has been erased
LOW BAT Alarm
The control panel has registered a low battery condition
LOW V #,# Alarm Expander #,# has detected that’s its supply voltage is low
MANUAL TEST CALL A Manual test call has been initiated
MIC ## TESTED Microphone ## on the Audio Verification Module has been tested
Monitored Alarm A zone programmed as key tube has caused an alarm
No RF Signal ### The Wireless receiver has detected a signal loss from zone ###
PA From Remote FOB A PA has been generated from a Remote Fob
Panel Line Fault The control panel line fault input has been activated
PART Armed Area ? has been Part Armed
PART 1 Armed Part Arm 1 has been selected
PART 2 Armed
Part Arm 2 has been selected
PART 3 Armed Part Arm 3 has been selected
POWERED UP System Power Up (without doing a factory restart)
POWER O/P FAULT The system has generated a Power Output Fault see Table Power ID Fault on Page 98
POWER UNIT FAILURE The system has generated a rate of voltage failure
PROG. END The Engineer has logged out of the Programming menu
PROG. START An Engineer code has been entered
PSUac ## Alarm An expander input programmed as PSU Monitor control panel has detected an AC Mains failure
PSUbat## Alarm An expander input programmed as PSU Monitor control panel has detected a Battery fault
PSUvol## Alarm
An expander input programmed as PSU Monitor control panel has detected a 12V Output failure

Table of Contents

Other manuals for Texecom Premier Elite 24