Engineer Utilities Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual
114 INS176-9
Log Event Description
PSUTam## Alarm An expander input programmed as PSU Monitor control panel has detected a Tamper condition
QUICK Armed Quick Arm from keypad #,#
R/Bat ## Alarm The Wireless receiver has detected a low battery signal from device ##
Radio Jamming The Wireless receiver has detected an attempt to jam its radio signal
RADIO PAD LOST The Radio-Pad has no signal or has lost communications with the control panel
REARM LOCK ### Zone ### has locked out after reaching its re-arm limit (after causing an alarm)
RECENT Armed
Area ? has been armed recently
Redcare Line Fault The Redcare has detected a line fault
REMOTE Armed Area ? was armed using the Wintex UDL software
REMOTE Disarmed Area ? was disarmed using the Wintex UDL software
Remote PC Reset A reset has been performed by the remote download PC
Remote Reset A reset has been performed using the ‘Remote Reset’ input
Redcare Reset A reset has been performed by the Redcare
RF Device ###Low Battery RF Device ### has registered a low battery condition
RKP #,# MEDICAL A Medical alarm (7 & 9) has occurred from keypad number #,#
RKP #.# FIRE
A Fire alarm (4 & 6) has occurred from keypad number #,#
RKP #,# AUD PA An Audible PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# SIL PA A Silent PA alarm (1 & 3) has occurred from keypad number #,#
RKP #,# Tamper The cover of keypad #,# has been removed
RKP #,# LOST Keypad ## has been lost from the network
RKP LOCKED #,# Keypad #,# has been locked out from too many invalid key presses
Site Data Changed Site Data has been changed e.g. zone ### has been changed
Supervision Fault A Radio device has failed to poll back to the panel within the Supervision Time
System Over Voltage The control panel Bell Fuse has failed
TAG ##
User ## has presented their Prox TAG
Test Call Passed
Manual or Periodical Test Call has passed
Test Call Failed Manual or Periodical Test Call has failed
TESTED ### Zone ### has been tested
TEST FAIL ###) Zone ### has failed its Soak test
TAG System Exit (Batt. OK) The system has been put in to exit via tag and battery voltage is ok
TAG System Exit (Batt. Low) The system has been put in to exit via tag and battery has low voltage
TAG System Entry (Batt. OK) The system has been put in to entry via tag and battery voltage is ok
TAG System Entry (Batt. Low) The system has been put in to entry via tag and battery has low voltage
TIME Armed Area ? was armed automatically using one of the control timers
TIME CHANGED
The control panel Date has been changed
TIME Disarmed Area ? was disarmed automatically using one of the control timers
TUBE ### Alarm Zone ### (programmed as Key Tube) has caused an alarm
USER ## User ## has entered their code
User Ack A user has acknowledged a fault to set system
USER CODE CHANGED A User code has been altered
USER ADDED A User code has been added
USER DELETED A User code has been deleted
User Reset
A reset has been performed using a User code
WALK Test Start
The Walk Test mode has been initiated
Zone ### Alarm Zone ### has been activated
Zone ### Tamper Zone ### has caused a Tamper alarm
Zone ### Restore Zone ### has restored to its normal condition
Zone ### Omitted Zone ### has been omitted
Zone ### Un-Omit Zone ### has been reinstated
Zone ### Test Start Zone ### has been put on test
Zone ### Test End Zone ### has been removed from test
Zone ### Fault
Zone ### has generated a Fault Condition
Zone ### Masked Zone ### has been Masked