Upper/Lowercase, Predictive text and Clear Screen
The control panel also features Predictive text. This can be used to
make inserting words easier, i.e. when spelling the word PIR, instead
of typing 7444777, all that you need to do is type 747 and the word is
automatically selected.
This feature can be turned on and off as required by pressing
the
O
key and can also be automatically selected every
time text mode is entered (see page
64
for details).
Copying and Pasting
When programming any items i.e. Zones, Timers, Options etc.
pressing CHIME at any point will ‘Copy’ the information that has just
been programmed into memory. To program another item using the
information in memory, select the item and press PART to ‘Paste’ the
information.
Copying and Pasting can only be performed whilst in the same
option i.e. if a zone has just been programmed as Guard
1/Omit/Access/Areas-ABC, ALL of that information can be
copied into memory so that when another zone is selected, the
same information can then be quickly pasted to the other zone.
The information held in memory after programming an item can only
be pasted into an item of the same type and cannot be used once
another option is selected i.e. Zone programming information cannot
be pasted into Timers etc.
Log Off Engineer
Whenever the Engineer Programming menu is exited by pressing
R
twice, the display will look like this:
Thi
s message will remain on the display until the Engineer logs out of
the Programming menu.
To log out of Engineer Programming menu, proceed as follows:
Enter an Engineer code
, the display should
look like this:
Press
0
or
R
, the display should look like this:
Press
y
to return to normal, the display will look something like
this:
The Engineer is now logged out of the Programming menu.
The Engineer will be automatically logged out when the
Engineer Logoff Delay Timer Expires (See Page 63)
Resetting the Engineers Code (User 00)
If the Engineer code (User 00) has been lost or forgotten, it can
normally be reset back to the factory default of
1234
. However, this can only be done if the NVM
has not been locked (see page
64 f
or details).
To Reset the Engineer code (User 00):
ENSURE THAT THE LID TAMPER IS CLOSED
Hold down the ‘Factory Default’ button for 6 seconds (with the
control panel still powered), after 6 seconds, the sounders/keypads
will bleep to indicate that the Engineer code has been reset.
NO other codes/programming will be affected, it is just the
User 00 Engineer code that will be reset.
The Engineer (User 00) code can only be reset, if the NVM has not
been locked (see page 64 for details).
Other Things to Know
The N key will always return to the previous menu level. This is
often the only way to exit an option after programming it. Pressing
N several times will always return to the top level menu and the
logout screen.
The
A,O,P,C and R keys often provide shortcuts or
extended functions, refer to individual programming options for
details.