Premier Elite 24,24-W, 48,48-W, 88, 168 & 640 Installation Manual Setup Users
INS176-9 109
User Functions and Options
The table below shows the options that are available to each user.
All users that have access to the ‘Arming Menu’ have the ability to ‘View Zone Status’, ‘Set Chime Areas’, ‘View Act. Faults’ and ‘View Act.
Counts’.
All users have access to the ‘User Menu’ have the ability to ‘View Event Log’, ‘Adjust Volumes’ and ‘Print Event Log’.
User Options 1
Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Custom
Arming Arming Arming Arming Arming Arming Arming - Arming -
Disarming Disarming Disarming Disarming Disarming Disarming - - Disarming -
Omitting Omitting Omitting Omitting Omitting Omitting - - Omitting -
Eng. Reset - - - - - - - - -
- - - - Local Arming - - - - -
- - - - Local Disarm - - - - -
- - - - - - - - - -
Disarm First Disarm First Disarm First Disarm First Disarm First Disarm First - - Disarm First -
User Options 2
User Menu User Menu User Menu User Menu User Menu - User Menu - User Menu -
Eng. Program - - - - - - - - -
- - - - - - - -
-
-
- - - - - - - -
Vacation
-
Door Strike Door Strike - - - - - Door Strike - -
Call Rem. PC Call Rem. PC Call Rem. PC - - - - -
-
-
- - - - - Duress Code - - - -
Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close - Open/Close -
User Config.
Engineer Master Manager Standard Local Duress Arm Only Door Strike Vacation Not Used
Change Code Change Code Change Code Change Code Change Code - - - - -
Chime Zones Chime Zones Chime Zones Chime Zones Chime Zones - - - - -
Change Timer Change Timer Change Timer - - - - - - -
System Tests System Tests System Tests - - - - - - -
Setup Users Setup Users - - - - - - - -
Eng. Access Eng. Access Eng. Access Eng. Access Eng. Access - Eng. Access - Eng. Access -
Add Eng. code - - - - - - - - -
NVM Locking - - - - - - - - -