Operator Manual, Revision T-170
prevent damage to a profile part.
LINE DELAY-TIME: Use this function for big thicknesess - set this delay time for cutting in the corners
or when the torch change the direction
SELECT HI HOTUP M24 (0/1): Function not used with EX-TRACK
®
CNC SYSTEM.
GAS ON M ORDER: Function not used with EX-TRACK
®
CNC SYSTEM.
9.9. Plasma parameters
The plasma parameters are accessed in the SETUP menu by pressing the [F4] key.
FIND IHS HEIGHT (0/1): switch on initial height sensing for plasma torch.
IHS LOGIC: set this to 0 for EX-TRACK
®
CNC SYSTEM working with the EX-TRAFIRE
®
PLASMA
SYSTEM
IHS TIMER: turn on automatic initial height sensing when re-starting after pausing a program.
TORCHUP TIME (M70): torch retracts for short period prior to starting the IHS sequence.
TORCHDN TIME (M71): timer used to lower the torch at the end of the pierce sequence.
USE ARC-ON SIGNAL: receive arc-on signal from the plasma power supply prior to activating travel.
MAX TIME FOR ARC- FEEDBACK(S): exceeding the arc-on signal waiting time creates an error.