EX-TRACK
®
Operator Manual, Revision T-174
POSITION UP TIME: piercing and cutting height in seconds - time of lifting up the torch after IHS
touch of the plate.
ARCING CHECK TIME: during checking main arc on feedback, if during the set time, still no measure
the “ok to move” signal, then automatic shut off the start arc signal.
MANUAL SPEED: the torch up/down speed for manual lift (up down manual speed).
AUTO SPEED: the torch up/down speed for automatic lift.
POSITION SPEED: the torch up/down speed for the initial position.
9.9.3. Save [F7]
This key save all adjusted parameters to the internal memory of EX-TRACK
®
unit.
9.9.4. Gallery function
The gallery function is accessed in the Main Menu by pressing [F6].
9.9.5. Graphics library
The library contains 50 geometrical shapes; the shapes can be dimensionally altered. The arrow
keys [↑] [↓] [←] [→] are used to locate a shape, then [ENTER] to select. See Appendix for Shape
Library Variables.