EX-TRACK
®
Operator Manual, Revision T-188
Fault This may
mean
Cause Solution
One of the
motors does
not turn.
• Check wiring
from drive amp
to motor.
• Loose connection. • Secure all wiring
connections.
• Check the drive
amplifier.
• Check for any
alarms or if the
settings are not
correct.
• Correct settings of drive
amp.
• Check settings
of SYSTEM
parameters.
• Check if Start
Speed is zero
or too high, the
Acceleration Time
is too short, or
Numerator and
Denominator
settings are set
incorrectly or set to
zero.
• Set the parameters to the
appropriate settings. Be
sure to record the original
parameters before making
any modification.
• Check motor
to make sure it
is not frozen or
jammed.
• Motor may be
damaged.
• Replace motor if damaged.
CNC is slow to
respond.
• Check the power
supply.
• Output voltage
may be below the
allowable range.
• Adjust the output voltage or
replace the power supply.
• Check settings
of SYSTEM
parameters.
• Corrupt or incorrect
parameters
may cause CNC
operating issues.
• Set the parameters to the
appropriate settings. Reset to
factory settings if necessary.
Be sure to record the original
parameters before making
any modification.
Travel limit
alarm at power-
on.
• Check settings
of SYSTEM
parameters.
• Machine position
may be outside
settings for Soft
Limits.
• Press Off Line button,
manually move torch head
to normal cut area, try to run
again. Increase settings for
Soft Limits if necessary.

Table of Contents