EX-TRACK
®
Operator Manual, Revision T-194
The system firmware of controller can be updated through a USB stick. In case a system software
update is supplied by THERMACUT and needs to be installed, carefully follow this procedure:
1. Copy the update file titled STARTCNC.EXE to a USB stick.
1. The USB stick should be freshly formatted as FAT or FAT32 format. The STARTCNC.EXE file
should be the only file on the USB stick.
2. Press and hold the Software Update button while the system power is switched on.
Continue to hold the button until the upgrading window appears on the display screen.
3. Plug the USB stick into the port and press the [F1] key to select UPDATE. The system will
automatically start the update operation.
4. If the update is successful, the system will display “PLEASE REBOOT”, and sound two beep.
If the update fails, the system will display “UPDATE FAILED”, and sound continuous beeps.
5. Power the system off and unplug the USB stick. Reboot the system to start up the updated
system. The version number of the updated system software will appear on the screen after
boot-up.
Note: If the update fails, check the following:
2. The USB stick must be FAT or FAT32 format. FAT is preferred.
1. The update file must be named STARTCNC.EXE.
If no prompt appears in the updating process and the display returns to the main updating window
or updating fails due to any other interruption, first verify the name of the update file and the
USB formatting. If these two factors are confirmed, attempt the update again following the above
procedure. If the update fails again, contact THERMACUT
®
Technical Support for assistance.